Two-way RTI control of the WyreStorm MX-0404-SCL 4x4 seamless matrix over RS-232 or IP - routing, multiview, video wall, CEC, EDID, scaling and presets, with polled feedback throughout.
Complete two-way control of the WyreStorm MX-0404-SCL 4x4 seamless matrix from RTI, over RS-232 or the network. Every published command is implemented, and because the matrix never reports changes on its own, all feedback is polled - so a front-panel or web-UI change still shows up on the panel.
Includes a 120-minute free trial - load it and it works immediately, no key needed. After the trial, control commands stop while feedback and polling keep running. The licence key is tied to the RTI processor MAC address, shown in the MAC For Key system variable.
Features
- 16 discrete crosspoints - every input-to-output route as its own tag, each a paired command and feedback tag so a single drop wires the button and its highlight together.
- Multiview - all six layouts with per-window source assignment, plus audio-follows-window selection.
- Video wall - send any source across all four displays as a 2x2 wall.
- CEC display power - per output or all at once, with auto-CEC control and the no-signal power-off delay exposed.
- Per-output scaling - auto, manual and bypass, plus 26 fixed output resolutions. The driver switches the scaler to manual for you when you pick a resolution.
- EDID management - copy-from-output and the fixed 4K and 1080p presets, with the reserved values blocked so an invalid parameter can never reach the unit.
- Presets, standby and de-embedded audio zones all covered.
- Browser dashboard - a live 4x4 crosspoint grid with multiview, presets, CEC and scaler pages. Runs on the processor: open it in a browser or drop it into an RTI Web Object.
- Text tags for every value - routing, names, firmware, resolutions, EDID, layout and status all drop straight into button text.
- Diagnostics built in - a telnet console with a full routing table, multiview state, a read-only protocol probe and a wiring checklist for a dead serial link.
- Sample project included - a 17-page Integration Designer file with all 111 commands and 121 feedback variables already placed and wired.
- WyreStorm MX-0404-SCL 4x4 seamless matrix
- RTI processor with a spare RS-232 port, or network access to the matrix on TCP 23
- Integration Designer 11.4 or newer, driver runtime 24 or newer
- RS-232 wiring needs three conductors including signal ground - omitting ground is the most common cause of a dead link